Bus Voltage Monitoring
Multi-Point Bus Voltage Monitors with Trip Outputs
Multi-point bus voltage monitors are electrical protection assemblies that measure electrical potential across twenty power bus segments to directly trigger load-shedding and circuit isolation. Constructed from precision voltage dividers, radiation-hardened operational amplifiers, and hardware comparators, the two-kilogram subsystem operates on three watts of power with 0.5 percent measurement accuracy. Because electrical stability is critical to lunar life-safety systems, the monitor bypasses central processor intervention entirely, executing hardware trips within one millisecond. To prevent spurious trips caused by space radiation while ensuring continuous fault detection across a 25-year operational lifetime, the subsystem employs multi-threshold trip points and voting logic across redundant sensors.
Voltage monitors at every bus segment with hardware trip outputs feeding load-shed and isolation circuits.
Purpose
Voltage monitors at every bus segment with hardware trip outputs feeding load-shed and isolation circuits.
Context
Child of L2-PDM-MON within the Lunar Ark system
Principles
- ▸Precision voltage dividers + rad-hard op-amps
- ▸Hardware comparators trigger trip without CPU intervention
- ▸Multi-threshold trip points for graceful response
- ▸Voting logic across redundant sensors
- ▸Calibration drift compensation
Typical implementations
- ▸ISS bus voltage monitoring heritage
- ▸Industrial power monitoring devices
- ▸Spacecraft RPC voltage sensing
Lunar considerations
- ▸Hardware trip critical for life-safety
- ▸Sensor redundancy avoids spurious trips
- ▸Sub-millisecond response time
Specifications
Functional
| primary function | Voltage monitors at every bus segment with hardware trip outputs feeding load-shed and isolation circuits. |
| sense points | 20 |
| trip response ms | 1 |
| accuracy percent | 0.5 |
Physical
| mass kg | 2 |
| materials | Precision voltage dividers, Rad-hard op-amps, Hardware comparators |
| vacuum compatibility | True |
Operational
| power consumption w | 3 |
| thermal range c | -40, 70 |
| lifetime years | 25 |
| mtbf hours | 300000 |
Interfaces
Provides
- Trip signals to isolation contactors
- Voltage triggers
Requires
- Voltage sense taps
Cite this entry
Lunar Ark Codex. "Bus Voltage Monitoring" (L3-PDM-MON-VOLT). Retrieved 10 September 2026, from https://lunarark.com/entry/L3-PDM-MON-VOLT
Licensed CC-BY-SA 4.0. You may reuse and adapt this entry with attribution, under the same licence.